In many locations from chemistry laboratories to industrial services, to have the ability to ensure the security of life and property in opposition to a potential fireplace hazard, extinguishing techniques are used along with detection and alarm systems. It can be extremely necessary that the extinguishing methods installed can be triggered by the hearth extinguishing management panel, to find a way to eliminate a possible fire with early intervention.
In order to fulfill these wants, and with 35 years of sectoral data and expertise, Mavili Elektronik offers:
Maxlogic Conventional Fire Extinguishing Control Panel working in accordance with the cross-zone detection principle;
Maxlogic Extinguishing Status Indicator Unit, which permits the remote efficiency of the indications and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which permits the extinguishing course of to be started manually and remotely; and
to guarantee that the extinguishing process could be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
เพรสเชอร์เกจ are produced using surface-mount expertise and are aimed toward making the automation of the extinguishing system and hearth and fuel detection system good.
Image copyright: Mavili
Mavili Elektronik develops its products by always contemplating the wants of the installation. In cases that require the mixing of the extinguishing system with the clever addressable fireplace detection system, it supplies solutions via the monitoring modules that also have a ‘supervised’ choice.
Supervised monitoring modules play an essential function in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a attainable open or brief circuit within the wiring between the contact monitoring modules and the peripheral techniques may cause disruption of the triggering, with doubtlessly important penalties. For this reason, when choosing monitoring modules, it should be taken into account that they have supervised options.
Image copyright: Mavili
Since Maxlogic clever addressable fireplace detection and alarm control panels are constantly communicating with ‘supervise’ contact monitoring modules linked to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it easier to watch conditions corresponding to open circuits and brief circuits which will occur in the system. Many duties may be carried out within the hearth extinguishing installation, such because the control and monitoring of all valves that may interrupt the flow of water, water move alarm switches, strain change, and electric or diesel fire pumps.
By adding two contact monitoring modules to 2 separate relay outputs positioned above the Maxlogic Conventional Fire Extinguishing Control Panel, one of the modules can be utilized to regulate errors and the opposite to regulate the fire scenario, monitoring and management of the extinguishing system via an clever addressable hearth detection and alarm system could be carried out effectively.
For extra information, go to www.mavili.com.tr/en