A diaphragm seal system in vacuum pressure process must master a significant challenge ? it must deliver a reliable measuring result, even when the pressure drops and the temperature rises concurrently. The example of a chemical company producing phthalic anhydride (PA) demonstrates it is in no way self-evident that this requirement could be met on a frequent basis.
PA is primarily used as a plasticiser for plastics. However, it is also found in the production of synthetic resins and dyes. Perplexed obtains this compound via the catalytic oxidation of o-xylene in the gas phase, accompanied by a vacuum distillation process.
Critical phase for pressure measurement
In this process, the critical phase for pressure measurement occurs in the distillation column. There, the process temperature can rise to more than 230 �C while the pressure drops to 100 mbar abs. With this type of contrary action, the traditional installed measurement technology reaches its performance limit relatively quickly, which the aforementioned manufacturer was forced to find out ? all instrumentation showed a measurement deviation outside the defined tolerance after only a fortnight.
Diaphragm seal system adapted in all elements to the vacuum process
The diaphragm seal system is tailored exactly to the conditions of the vacuum process and tested under application conditions.
Consequently, Panicked approached WIKA with the obtain a measuring solution that could also fulfil its task with the required accuracy in the long term beneath the conditions described. WIKA then drew on its in-depth expertise to create a diaphragm seal system for the vacuum process, comprising an activity transmitter (model IPT-20), a flange-type diaphragm seal with flush diaphragm (model 990.27) and a capillary.
All components of this measuring system were selected specifically for the application. Silicone oil KN32 was therefore selected because the fill fluid for pressure transmission. The cleaning and conditioning of the diaphragm seal, the capillary, the bond pieces as well as the automated filling process were also matched to each other exactly. With sensitive limit ranges, even one drop of liquid an excessive amount of or inadequate can destabilise the quantity balance of the diaphragm seal system and thus impair its function. Therefore, correct measurement would no more be guaranteed.
Test under application conditions
After cleaning, all parts of the diaphragm seal system were first fully welded right into a single unit as usual, accompanied by the filling and adjustment of the system. Before delivery, however, there is another crucial step ? in its laboratory, WIKA simulated vacuum pressure process for the diaphragm seal system in accordance with the customer? Targeted and subjected it to a thermal ageing process. This test confirmed the process suitability of the measuring system.
Note
More info on the WIKA diaphragm seal systems can be found on the WIKA website. In case you have any questions, your contact will gladly help you.
Also read our posts
Diaphragm seals for stable flow measurement in deep seas
How do diaphragm seals work?
Watch the following video to learn more concerning the functionality, application areas and benefits of diaphragm seals:

Leave a Reply